Here are the specifications for your
Ultimizer Wood Series BL 4044:

  • 500,000 approx. BTU/hr
  • Heats up to 12,000 sq. ft.
  • 72″ x 57″ x 92″
  • 3500 lbs. (shipping weight)
  • 47″ x 38″ x 48″ Fire Chamber
  • 160 Gallon (US) water capacity
Sectional Boiler, Refractory Lined, Dry Base

MODELS
BL 25X34 | 28X40 | 34X44 | 40X44

THE ULTIMIZER WOOD SERIES

The Ultimizer wood series is the product of more than 50 years of research and development that has earned Portage & Main Outdoor Boilers the reputation as an industry leader. With four sizes available, heating from under 2,000 sq ft to 12,000 sq ft, producing up to 500,000 BTUs. The Ultimizer can be connected to virtually any existing forced air or hydronic radiant heating system. Heat your home, domestic hot water, other buildings, hot tub, swimming pool, and more. In case you are looking for an EPA approved Wood Gasification Boiler we suggest you have a look at www.polarfurnace.com

Ultimizer Wood Boiler BL 4044

Portage & Main – Fireglow Process

01

Less Wood | Save Money

Portage & Main conventional boilers have set the bench mark for efficiency for over 50 years. Our boilers burn 33 – 50% less fuel than any other brand

02

Optimum burn | Save Time

Our R&D team designed a conventional/gasifier boiler to achieve optimal combustion with a refractory firepot lining 

03

12+ Hours Longer Burn

Our technology turns smoke into usable heat. This sectional boiler design resulted in user friendly, low maintenance & higher efficiency boiler

Unique Features & Benefits

Portage & Main Ultimizer

Legend

1st : First pass
2nd : Second pass
3rd : Third pass
4th : Fourth pass
A. Refractory brick lining & dry base design
B. Air from above & below
C. Full length quad-pass heat exchanger and upper baffle
D. Water – cooled rear baffle
E. Sectional, easy to repair design

A. Refractory Brick Lining

The Portage & Main Ultimizer is a refractory lined, dry base boiler. In the industry it has become known as an “updraft gasifier” because of its efficient burn. The Ultimizer is simple to use, easy to maintain and not fussy about the fuel it burns. It is very important to understand the “fire triangle” in order to fully appreciate the advantages of the Ultimizer design, and how it will save you fuel, money and time. To achieve a clean, efficient burn with complete combustion, an optimal balance of OXYGEN, HEAT & FUEL is required. The Portage & Main Ultimizer has been specifically designed to achieve this optimal balance.

Dry base design, zero ash line corrosion & no bridging 
The heat stored in the refractory lining helps ensure that a more complete combustion process occurs. I.e. fuel is reduced to charcoal in a 3-stage process.

STAGE 1: The fuel is heated to evaporate and drive out moisture. This starts at 212 degrees F

STAGE 2: It starts to break down on a chemical level at 500 degrees F. Volatile matter is vaporized. These vapors contain 50% to 60% of the heat value of the fuel, making it imperative for them to be burnt properly at a temperature in the range 1100 degrees F for maximum combustion efficiency. When all the volatile gases have been released, the remaining material is charcoal

STAGE 3: Charcoal burns at temperatures in excess of 1100 degrees F. Latent heat also helps in the re-ignition of the fire at the start of the next burn cycle. It also helps to dissipate moisture that is a result of the combustion process. The dry base boiler design gives a very hot burn. The water jacket sits above the brick line so it isn’t up against the fire, taking away the heat prematurely. This eliminates ash line corrosion and the fuel is completely burnt, resulting in considerably less ash.

B. Air from above & below

Exhaust gases make their 1st and 2nd pass at the top of the firebox where they move under and around a water-cooled baffle and into the heat exchanger. Gases then travel to the front of the boiler in a 3rd pass, make a 180 degree turn and move in a 4th pass to the back of the heat exchanger. In this way, all available heat is taken from exhaust gases before they exit the chimney. It gives up to 50% more heat transfer compared to other non water-cooled, non brick lined designs.

C. Full length quad-pass heat exchanger and upper baffle

The Ultimizer heat exchanger runs the full length of the boiler. It is completely surrounded by water which gives maximum heat transfer.

D. Water-cooled rear baffle

The water-cooled baffle at the rear of the Ultimizer fire pot absorbs heat and traps combustion vapors. Turbulence is created when air is introduced from below and above the fire. This turbulence provides an optimal burning environment for the vapors, leading to a hotter and more efficient burn. Also, by trapping the vapors, they are thoroughly burnt before entering the high efficiency heat exchanger. This heat exchanger is totally surrounded by water for maximum heat transfer.

E. Sectional, easy to repair design

Not a throwaway design like other brands are. The Ultimizer weighs substantially more than other brand boilers. That’s due to the heavy weight, long lasting, quality materials that go into our design. It provides a long-term, sustainable solution to your heating needs. At the end of its long life, the water jacket can be replaced. Just remove the top half of the boiler and bolt on a new top section, no welding required and your trusty boiler is good to go again. This means a very sustainable warranty, resulting in savings for the customer of several thousand dollars by rebuilding rather than replacing the entire boiler.

Most Trusted Outdoor Wood Boiler

since 1973

Request Quote

 

Register as a Dealer

 

Dealership Opportunity

Join our network of dealers across North America 

Portage and Main_Logo_2024

About Portage & Main

Our head office is located in Prince Albert, Saskatchewan, Canada. Our dealer network spans North America and we would be glad to put you in touch with one of our knowledgeable agents. Our staff oversees the development of new products, monitors production, designs heating systems, and offers tech support for installers. All our wood furnaces are designed for installation outdoors and deliver wood heat indoors.

Email

info@portageandmainboilers.com

Tollfree

1-866-301-4952

1-800-561-0700

Phone

(306) 922-1722

Hours

Monday-Friday : 8am to 5pm CST

Mailing Address

Courier Delivery

Follow Us

As seen on …
Toronto Star Logo

Request Quote

Submit

Dealer

If you are interested in becoming a dealer, please complete the form below. We look forward to speaking with you.

*Required field

*

*

*

*

*

*

*

Request Quote

We'd love to hear from you. Please complete the form below and we will respond within 24 business hours.

*Required field

*

*

*

*

*

*